DL/T 1044-2007 钢弦式应变计

附件大小:0.47MB
附件格式:1个直链文件,格式为pdf
所属分类:电力能源
分享会员:
分享时间:
最后更新:
资源简介/截图:

ICS 27.140
P 55
备案号:21251-2007
中华人民共和国电力行业标准
DL / T 1044 — 2007
钢 弦 式 应 变 计
Vibrating wire strain meter
2007-07-20 发布 2007-12-01 实施
中华人民共和国国家发展和改革委员会 发 布

DL/T 1044-2007,钢弦式应变计,DL/T 1044-2007 钢弦式应变计

目 次
前言··································································································································································Ⅱ
1 范围······················································································································································ 1
2 规范性引用文件·································································································································· 1
3 术语和定义·········································································································································· 1
4 产品原理、分类及规格 ······················································································································ 1
5 技术要求·············································································································································· 2
6 试验方法·············································································································································· 3
7 检验规则·············································································································································· 4
8 标志、包装、运输、储存··················································································································· 6
附录 A(规范性附录) 钢弦式应变计参数计算方法·········································································· 7

前 言
本标准是根据《国家发展改革委办公厅关于下达 2003 年行业标准项目补充计划的通知》(发改办工业[2003]873 号)要求制定的。
本标准附录 A 为规范性附录。
本标准由中国电力企业联合会提出。
本标准由电力行业大坝安全监测标准化技术委员会归口并负责解释。
本标准起草单位:基康仪器(北京)有限公司、国电自动化研究院。
本标准主要起草人:沈省三、刘广林、吴其均、王梅枝。
本标准在执行过程中的意见或建议反馈至中国电力企业联合会标准化中心(北京市白广路二条一号,100761)。

1 范围
本标准规定了钢弦式应变计的分类与规格、技术要求、试验方法、检验规则和标志、包装、运输、储存的要求。
本标准适用于大坝及其他岩土工程安全监测中测量结构应变的钢弦式应变计。
2 规范性引用文件
下列文件中的条款通过本标准的引用而成为本标准的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本标准,然而,鼓励根据本标准达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本标准。
GB 5603 负荷传感器名词术语
GB 5604 负荷传感器试验方法
GB 6388 运输包装收发货标志
GB/T 50123 土工试验方法标准
3 术语和定义
下列术语和定义适用于本标准。
3.1
频率模数 frequency modulus
频率的平方除以 1000,一个单位定义为“一个字”。
3.2
过范围限 overrange limit
能够加在钢弦式应变计传感器上不致引起性能永久性变化的被测量的最大值。
3.3
最小读数 mininum reading
钢弦式仪器在全量程范围内频率模数变化一个字时被测量的变化值。
4 产品原理、分类与规格
4.1 产品原理
钢弦式应变计主要由左右端座、钢弦和线圈等组成。
当被测结构物发生应变时,应变计左右端座产生相对位移并传递给钢弦,使钢弦受力发生变化,从而改变钢弦的固有频率。测量仪表输出脉冲信号通过线圈激振钢弦并检测出线圈所感应信号的频率,经换算得到被测结构物的应变量,其计算公式见附录 A。同时,由钢弦式应变计中的热敏电阻同步测出测点的温度值。
钢弦式应变计的基本原理及结构示意如图 1 所示。
4.2 产品分类与规格
根据安装方式,钢弦式应变计分成埋入式和表面安装式两类。

资源链接请先登录(扫码可直接登录、免注册)
十二年老网站,真实资源!
高速直链,非网盘分享!浏览器直接下载、拒绝套路!
本站已在工信部及公安备案,真实可信!
手机扫码一键登录、无需填写资料及验证,支持QQ/微信/微博(建议QQ,支持手机快捷登录)
①升级会员方法:一键登录后->用户中心(右上角)->升级会员菜单
②注册登录、单独下载/升级会员、下载失败处理等任何问题,请加客服微信
不会操作?点此查看“会员注册登录方法”

投稿会员:蒲公英二
我的头像

报歉!评论已关闭.

手机扫码、免注册、直接登录

 注意:QQ登录支持手机端浏览器一键登录及扫码登录
微信仅支持手机扫码一键登录

账号密码登录(仅适用于原老用户)