FIRE-GAS BSEN54-13:2017 BSIStandardsPublication Firedetectionandfire alarm systems Part13:Compatibilityand connectabilityassessmentofsystem ponents Adjustment :Ali Mohammad Akhavan DATE:10May2017 bsi.
BSEN54-13:2017 BRITISH STANDARD National foreword This British Standard is the UK implementation of EN 54-13:2017. It supersedes BS EN 54-13:2005 which is withdrawn. The UK participation in its preparation was entrusted to Technical Committee FSH/12/3 Control and indicating equipment. A list of organizations represented on this mittee can be obtained on request to its secretary. This publication does not purport to include allthe necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017. Published by BSI Standards Limited 2017 ISBN 978 0 580 84463 8 ICS 13.220.20 Compliancewith aBritishStandard cannotconferimmunity from legal obligations. This BritishStandard was published under the authority of the Standards Policy and Strategy Committee on 28 February 2017. Amendments/Corrigenda issued since publication Date Text affected
BS EN 54-13:2017 EUROPEANSTANDARD EN54-13 NORMEEUROPEENNE EUROPAISCHENORM February 2017 ICS 13.220.20 Supersedes EN 54-13:2005 English Version Fire detection and fire alarm systems-Part 13 Compatibilityandconnectabilityassessmentofsystem ponents Systemes de detection incendie - Partie 13: Evaluation Brandmeldeanlagen - Teil 13: Bewertung der de la patibilite et de I'aptitude au raccordement Kompatibilitat und AnschlieBbarkeit von des posants d'un systeme Systembestandteilen This European Standard was approved by CEN on 14 November 2016. so a ads pm saa a a m on pq ue s n this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions English French German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria Belgium Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland Formr Yugosla Republic f Macenia Fran Gemany Greece Hngary lceland Ireland Italy Latvia Lthai Luxembourg Malta Netherlands Norway Poland Portugal Romania Serbia Slovakia Slovenia Spain Sweden Switzerland Turkey and United Kingdom. EUROPEAN COM ARDIZATI0N COMITE EUROPEEN DE NORMALISATION EUROPAISCHES KOMITEE FUR NORMUNG
BS EN 54-13:2017 EN 54-13:2017 (E) Contents Page European foreword. .5 Introduction. ..8 1 Scope.... 2 Normative references. 3 Terms definitions and abbreviations . .10 3.1 Terms and definitions.... ..10 3.2 Abbreviations.. ..11 4 Requirements..... .11 4.1 Compliance. .11 4.2 Basic requirements. .12 4.3 Transmission path(s) .12 4.3.1 General. .12 4.3.2 TP using wires. .13 4.3.3 TP using radio frequency link. .13 4.3.4 TP using optical fibre ..13 4.3.5 Network TP ..13 4.4 Documentation.. ..14 4.4.1 General. ..14 4.4.2 Documentation for patibility ..14 4.4.3Documentation forconnectability .14 4.4.4 Software documentation. .15 5 Assessment methods and tests ..15 5.1 General. .15 5.2 5.3 Configuration Provision of equipment and supporting information and tools. .16 5.3.1 General. .16 5.3.2 Configuration at field level for assessment. .16 5.3.3 Configuration at control level for network assessment. .16 5.4Standard atmospheric conditions for testing. .17 5.5 Functional test for patibility assessment on field level. ..17 5.5.1 The objective of the test . .17 5.5.2 Test schedule .17 5.5.3 Functional tests for patibility in the different conditions. .18 5.6Functional tests for connectability assessment on field level. .22 5.6.1 The objective of the test. .22 5.6.2 Test schedule. .22 5.6.3 Functional test for connectability. .22 Annex A (informative) Example of levels used in FDAS. ..23 Annex B (informative) Classification of functions of the FDAS ..24 B.1 General. ..24 B.2 Fire detection function. ...24 2
BS EN 54-13:2017 EN 54-13:2017 (E) B.3 Fire alarm to occupants in the premises.. ...4 B.4 Fire alarm to summon external assistance (usually the fire brigade)... ...24 B.5 Activation of fire protection function.... ...24 B.5.1 Equipment directly triggered by the FDAS... ...4 B.5.2 Systems driven by the information ing from the FDAS.... ...24 B.6 Remote indication 1 (remote panels fire brigade panels etc.)... ...24 B.7Remote indication 2 (printers interface to building management system etc.)... ..5 B.8 Input function..... ...25 B.9 Output function. ...5 B.10 Devices used to connect transmission paths (gateway data switch etc.) ... ..25 Annex C (informative) Example methodology for theoretical analysis... ...26 C.1 Introduction.... ..26 C.2 Method oftest... ...6 C.2.1 General... ...6 C.2.2 List of characteristics ... ...26 C.2.2.1 Mechanical connections.. ...6 C.2.2.2 Power supply and distribution analysis. ...26 C.2.2.2.1 Voltage range.. ...26 C.2.2.2.2 Current... C.2.2.2.3 Supply characteristics... ..27 C.2.2.2.4 Power supply voltage range.. ...27 C.2.2.2.5 Fault performance... ...27 C.2.2.3 Data exchange analysis... ...27 C.2.2.3.1 General... ...27 C.2.2.3.2 Transmission characteristics . ...27 C.2.2.3.2.1 General. ...7 C.2.2.3.2.2 Voltage range .... ...7 C.2.2.3.2.3 Current... ...8 C.2.2.4Timing... ...28 C.2.2.3.2.5 Tolerances.... ...8 C.2.2.3.2.6 Fault performance... ...28 C.2.2.3.3 Transmission protocol(s) ...28 C.2.2.4 Functionality ...28 C.2.2.4.1 General. ...28 C.2.2.4.2 Received data... C.2.2.4.3 Transmitted data.. ...28
BS EN 54-13 2017 火灾探测和报警系统 第13部分 系统组件的兼容性和连接性评估.pdf
![1.3,54,BS,EN,连接性,国外标准](https://www.guifanku.com/wp-content/uploads/2025/02/thumb865565.jpg)