ICS 29.240.30  F 21
Record No. J486—2006
Electric Power Industry Standard of the People's Republic of China
P DL / T 5003 — 2005 To replace DL 5003 — 1991

Specifications for the Design of Dispatch Automation in Electric Power Systems

Issue Date: November 28, 2005 implementation Date: June 1, 2006
Issued by the National Development and Reform Commission of the People's Republic of China

DL/T 5003-2005,电力系统,自动化调度,英文版,设计技术,DL/T 5003-2005 英文版 电力系统调度自动化设计技术规程

1 Scope
These specifications are established to define the technical requirements for designing the master station of dispatch automation system in electric power system as well as the dispatch automation system of power plants (including hydraulic power plants, thermal power plants and nuclear power stations) and substations (including switchyard and DC converter stations).
These specifications are applicable to:
1.0.1 Planning, design, feasibility study design and preliminary design of the dispatch automation system in electric power system at province level and above.
1.0.2 Engineering design of the dispatch center of electric power system at province level and above.
1.0.3 Design of dispatch automation system of newly built, modified and expanded hydraulic power plants, thermal power plants, nuclear power stations and substations (including switchyard and DC converter stations) that are dispatched and managed directly by the dispatch center of electric power system at province level and above.

2 Normative References
The following normative documents contain provisions which, through reference in this text, constitute the provisions of thesem specifications. For dated references, subsequent amendments (excluding the contents of errata) to, or revision of, any of these publications do not apply. However, parties to agreements based on these specifications are encouraged to investigate the possibility of applying the latest editions of the normative documents indicated below. For undated references, the latest editions thereof apply to these specifications.
GB/T 2887 Specification for Electronic Computer field
GB/T 9813 Generic Specification for Microcomputers
GB/T 13729 Remote Terminal Unit Equipment
GB/T 18700.1 Telecontrol Equipment and Systems — Part 6: Telecontrol Protocols Compatible with ISO Standards and ITU-T Recommendations — Section 503: TASE.2 Service and Protocol (idt IEC60870-6- 503:1997)
GB/T 18700.2 Telecontrol Equipment and Systems — Part 6:Telecontrol Protocols Compatible with ISO Standards and ITU-T Recommendations — Section 802: TASE.2 Object Model (idt IEC60870-6-802:1997)
GB/T 18700.3 Telecontrol Equipment and Systems — Part6-702: Telecontrol Protocols Compatible with ISO Standards and ITU-T Recommendations — Functional Profile for Providing the TASE.2 Application Service in End Systems (idt IEC 60870-6-702:1998)

GB/T 18700.4 Telecontrol Equipment and Systems — Part 6-602: Telecontrol Protocols Compatible With ISO Standards and ITU-T Recommendations — TASE Transport Profiles (idt IEC 60870-6-602:2001)
GB 50174 Code for Design of Electronic Information System Room
DL/T 630 Technical Requirement for RTU with a. c. Electrical Quantities Input Discrete Sampling
DL/T 634.5101 Telecontrol Equipment and Systems — Part 5-101: Transmission Protocols — Companion Standard for Basic Telecontrol Tasks (idt IEC 60870-5-101:2002)
DL/T 634.5104 Telecontrol Equipment and Systems — Part 5-104: Transmission Protocols — Network Access for IEC 60870-5-101 Using Standard Transport Profiles (idt IEC 60870-5-104:2002)

DL/T 5202 Technical Code for Designing of Electric Energy Metering System

3 General
3.0.1 As the technical support system for operation of power grid,the dispatch automation in electric power system is now a major technical means for generation and dispatch of electric power. A dispatch automation system consists of the master station of dispatch automation system and the telecontrol system of power plants and substations (including switchyard and DC converter stations) (hereinafter referred to as plant/substation end). Although these specifications only serve as the design basis for the master station system and plant/substation end system of a dispatch automation system, it may also be used as a reference for design of other relevant parts in electric power system provided that the applicable design standards are observed.
3.0.2 As the dispatch automation design of electric power systems is a systematic task, it must be in line with the national economic development guidelines as well as various technical and economic policies. The dispatch automation of electric power systems shall be designed, based on the characteristics and actual operating conditions of the electric power systems, through using schemes that can meet the requirements in respect of reliability, practicability and cost effectiveness so as to enable safe and economic operation of electric power systems and allow for high quality of electric energy.
3.0.3 As an integral part of electric power systems, the dispatch automation system shall be designed on the basis of the design of the whole system (primary system) and on the grounds that the system dispatch management structure and the principle for division of dispatch management responsibilities are defined.
3.0.4 The dispatch automation design of electrical power systems shall be adaptable to the structure of unified dispatch and hierarchical management such that the electric power system is controlled byhierarchies and districts. The state-of-the-art and proven technologies suitable for the actual conditions in China shall be used for the overall system design in an effort to make it cost-effective and practical.
3.0.5 In designing dispatch automation of electrical power systems,the characteristics of power systems, operation requirements and availability of channels shall be analyzed to place the overall functional requirements of dispatch automation system and the requirements for telecontrol information and information transmission network. Also, the design of human-machine interface at the master station, the telecontrol system at plant/substation end and the automatic generation control systems shall be defined.
3.0.6 The engineering design of dispatch automation system of the dispatch center shall be based on the approved planning, design and feasibility study of dispatch automation of electric power system to determine the types and specifications of various equipment and layout diagram of system implementation scheme, develop the documents of preliminary design and construction drawings design,and coordinate with the engineering services such as design liaison and acceptance.
3.0.7 The engineering design of the dispatch automation system of power plants or substations (including switchyard and DC converter stations) shall be based on an approved one to verify the dispatching relationships among different equipment and the telecontrol information and to determine the types and specifications of equipment. Moreover, it shall finalize the information transmission channels, and develop ordering drawings, schematic wiring diagrams and wiring diagrams for installation on the premise that the regulations of safety protection for secondary power systems are observed. In case of hydraulic power plants and thermal power plants for which automatic generation control is employed, the interface with plant automation system shall be determined as well according to the adjustment modes (namely, single unit adjustment or group adjustment) of power plants.
3.0.8 In addition to the provisions herein, the dispatch automation design of electrical power system shall comply with the current national and industrial codes and regulations.

 

 

 

资源链接请先登录(扫码可直接登录、免注册)
十二年老网站,真实资源!
高速直链,非网盘分享!浏览器直接下载、拒绝套路!
本站已在工信部及公安备案,真实可信!
手机扫码一键登录、无需填写资料及验证,支持QQ/微信/微博(建议QQ,支持手机快捷登录)
①升级会员方法:一键登录后->用户中心(右上角)->升级会员菜单
②注册登录、单独下载/升级会员、下载失败处理等任何问题,请加客服微信
不会操作?点此查看“会员注册登录方法”

投稿会员:芳华
我的头像

您必须才能评论!

手机扫码、免注册、直接登录

 注意:QQ登录支持手机端浏览器一键登录及扫码登录
微信仅支持手机扫码一键登录

账号密码登录(仅适用于原老用户)