2014年5月下 施工技术 第43卷第10期 CONSTRUCTIONTECHNOLOGY 59 DOI:10.7672/sgjs2014100059 接建钢结构悬挑梁节点构造设计与施工 郭小明,刘云鹏,谢亚军,王学智 (建研(北京)结构工程有限公司,北京100013) [摘要】针对某既有框架结构建筑,为增加使用面积,采用钢结构与压型钢板组合楼盖体系,对原结构进行接建施 工。
通过施工难点分析和方案比选,为避免截断原柱钢筋,降低结构强度,通过采用等强代换的方式,确定采用钢 抱箍和植螺栓的方式。
结果表明,采用该方法能确保与原柱梁节点区连接节点的有效连接,同时也保证了改造后 结构的安全性和可靠性。
[关键词】改造;节点;钢结构;设计;施工 [中图分类号]TU746.3 [文献标识码】A [文章编号]1002-8498(2014)10-0059-03 JointDesignandConstructionofEnlargeSteelCantileverBeam Guo Xiaoming,LiuYunpeng,XieYajun,Wang Xuezhi (Jianyan(Beijing)Construction Engineering Co.,Ld.,Beijing100013,China) Abstract:A existing frame building need to be reconstructed to enlarge the using area,and the steel structure with profiled steel sheet system is adopted.Through construction difficulties analysis and scheme selection, the steel hoop and planting screw are adopted after replacing reinforcement with equal intensity,the choice reason is to avoid cutting column's reinforcement and reduce the structure strength. The using results show that the joints of steel with original beam and column are ensured, and the safety and reliability of the reconstruction structure are guaranteed. Key words:reconstruction;joints;steel structures;design;construction 1工程概况 新增埋件板的背面为原梁钢筋弯折收头处,左右两 北京金地中心商业区原为钢筋混凝土框架结 侧原结构梁钢筋水平贯通或弯锚,原结构柱28根 构,地下2层,地上3层,为增加使用面积,原室内1 Φ28钢筋竖向贯通,箍筋为6肢箍$8@100双向布 层顶、2层顶、3层顶原预留较大洞口封堵一部分,采 置。
原框架柱为斜柱(斜7°),柱截面为 用钢结构与压型钢板组合楼盖体系,新增悬挑钢梁 750mm×750mm。
最大净长度4.6m,2层顶结构如图1所示。
原方案为穿柱植16根M36螺栓(孔径60mm), ③ 上下各8根,正面中间区域需植人20根M30螺栓 (孔径32mm),植深630mm。
原方案如图2所示(未 填充阴影部分为 G 体现柱斜度及原梁情况)。
2施工难点分析 在接門点区域 1)正面中间区域需钻20个Φ32mm的孔,实际 9000×11 做样板,电锤成孔后,因原梁柱交点处纵横向钢筋、 箍筋较多及植螺栓孔径较大、较深,均不能满足 图12层顶结构布置示意 要求。
Fig.1Layout of the second floor structure 2)上下穿柱钻8个Φ60mm的孔,理论计算尺 图1曲线内原柱其中3个面均为原结构框架 寸66.6mm((柱宽750mm-保护层30mmx2-钢筋 梁,形成“T"形节点区域,且此处为梁柱节点区域, 直径28mm×8)/7=66.6mm),此孔径只能采用水 钻成孔。
[作者简介】郭小明,助理工程师,E-mail:18601120693@126. 上述2条分析,如果使用水钻成孔(成孔是一 [收稿日期】2013-08-22 条直线),必会切断原结构钢筋、箍筋,原结构施工 万方数据
60 施工技术 第43卷 12 二 1280]25 植M36螺栓 50.801 M22高强螺栓配 原混凝土 Q345B 梁顶标...