2011年3月下 施工技术 第40卷第337期 CONSTRUCTION TECHNOLOGY 47 某办公楼加固改造工程设计与施工 吴剑平 (天地金草田(北京)科技有限公司,北京100013) 【摘要]针对砖混结构的特点,通过建模对某办公楼进行了计算分析.提出了采用钢屋架代替混凝土梁板的做法 以减轻自重,同时增加构造柱及圈梁提高结构的抗震性能.介绍了植筋、灌浆料及钢结构的施工工艺,并重点对拆 除施工中的技术方法,预防措施进行了分析.技术方案及施工质量符合规范要求. 【关键词]加固改造:钢屋架:构造柱:圈梁;抗震 [中图分类号]TU746.3 【文献标识码]A【文章编号]1002-8498(2011)06-0047-02 Strengthening Design and Construction Technology of an Office Building Wu Jianping (Tiandi JCT Beijing)Science Technology Co.Lad.Beijing 100013 China) Abstract:Based on characteristics of masonry structure an office building was calculated and analyzed by establishing structure model.The method that replacing conerete beams and slabs with steel roof truss to reduce the structural weight and setting the structural columns and ring beam to improve the seismic performance were proposed.At the same time the construction technology of planting steel bars grouting materials and steel structure were introduced.The demolition technology and preventive measures were analyzed especially.The technology program and construction quality can meet the requirements of codes. Key words:reinforcement;steel roof truss;structural column;ring beam:seismic 1工程概况 某办公楼于20世纪50年代建成,为主体4层、 局部5层的砖混结构,层高3.8m 女儿墙高1.25m 主体结构总高16.35m(见图1),采用前苏联抗震设 计规范进行了7度抗震设防设计.由于受当时经 济、技术、施工条件的限制,建筑本身的使用功能不 正立面 b屋盖布置 能满足办公要求.为了保留其原有历史风貌,决定 图1办公楼示意 Fig.1 The office building 在不破坏建筑外观的情况下进行改造,使4层东西 震加固技术规程》JGJ116一2009和《钢结构设计规 两侧顶层办公室层高增加1m.4层东西两侧办公 范》GB50017一2003为主要依据,以保证原挑檐的 室尺寸为10.8m×11.8m 为井字屋盖,上部为 稳定性为原则进行改造设计...