2015年8月下 施工技术 第44卷第16期 CONSTRUCTIONTECHNOLOCY 23 DOI:10.7672/sgjs2015160023 某在役砖混结构小学教学楼加固设计* 贾文峰,张春生,樊济喜,丁亚红 (河南理工大学土木工程学院,河南焦作454000) [摘要]针对某在役砖混结构小学教学楼的破坏特点,参照相关建筑抗震设计规范,采用外加捆绑式构造柱、增设 钢筋网水泥砂浆面层以及楼板端部设置角钢的加固方法对其进行抗震加固设计。
通过对加固方案进行系统计算 分析,该加固方案能有效增强结构的整体性,提高其综合抗震能力,延长使用寿命。
[关键词]加固;砖混结构;抗震;构造柱;钢筋网水泥砂浆;设计 [中图分类号】TU746.3[文献标识码】A【文章编号】1002-8498(2015)16-0023-04 StrengtheningDesignofaBrickStructureofExisting Primary School Building JiaWenfeng,ZhangChunsheng,FanJixi,DingYahong (CollegeofCivil Engineering,He'nanPolytechnicUnitersity,Jiaozuo,He'nan454000,China) Abstract:Based on characteristics of destruction,according to relevant seismic design of building,a brick structure of existing primary school building has been carried on the ways of adding bundled structural column,the mortar surface layer of steel mesh,angle steel on the end of the floor to conduct strengthening design. Through calculation and analysis of the strengthening scheme,the ways can service life of the structure. Key words:strengthening;brick buildings;aseismic; structural column;mesh reinforcement cement mortar; design 20世纪七八十年代,砖混结构因其构造简单、构进行抗震鉴定与加固(。
施工方便、造价低等特点,在我国大部分地区的民1工程概况 用住宅和学校建筑中应用十分广泛。
但组成砖混本工程为河南理工大学附属小学教学楼,4层 结构的基本材料和连接方式决定了其脆性性质、变内廊式砖混结构,楼长93.6m,楼宽20.8m,1~4层 形能力小,导致房屋的抗震性能比较差。
另外,由层高均为3.6m,建筑高度为15.4m,建筑面积 于施工条件限制等原因导致大部分砖混建筑存在4386.38m²。
纵横墙承重,墙厚240mm,楼板为预制 抗震设防标准不足甚至未进行抗震设计等问题。
空心板,该结构设有混凝土梁和圈梁,没有设构造 在自然老化和人为因素影响下,多数早期砖混结构 柱。
该工程抗震设防类别为重点设防类,按7度设 开始出现安全性问题,学校建筑目前已成为抗震性防,8度抗震措施,地震基本加速度为0.15g,计划经 能极为薄弱的最大隐患。
比如墙体出现裂缝、地基过抗震加固后,后续合理使用年限为40年。
产生不均匀沉降、楼板脱落等,特别是近年来发生 2抗震鉴定情况 的汶川大地震、玉树地震,砖混结构毁灭性的破坏 在现场对该建筑进行外观检测,教学楼的梁、 给我们敲响了警钟。
为此我国提升了砖混结构中 板、柱等主要承重构件基本完好,墙体也基本完好, 小学建筑抗震设防标准,并逐步开展对既有砖混结 但个别墙体有面层脱落现象。
原图纸设计,1~4层 为Mu10砖,M5.0混合砂浆砌筑。
经检测,砂浆强 国家自然科学基金():河南省软科学研究 度等级为M2.5。
同时,依据建筑抗震设计规范,利 () 用PKPM软件对原结构进行抗震计算,房屋1~4层 [作者简介]贾文峰,硕士,E-mail:1033646141@ 多个墙肢抗力与效应比值小于0.8,验算结果显示 [收稿日期]2015-03-02 万方数据
24 施工技术 第44卷 建筑各层均存在抗力与荷载效应比(<1)不满足规 造柱相连)与原圈梁形成闭合系统。
范要求的墙段,不满足抗震承载力的要求。
4)新建构造柱应设置基础,埋深与...