施工技术 2017年8月上 46 CONSTRUCTION TECHNOLOGY 第46卷第15期 D0I:10.7672/8js2017150046 某工程预应力悬挑梁施工难点及控制要点* 张伟,周支军,李阳,张中善,包正 (中国建筑第七工程局有限公司,河南郑州450004) [摘要]介绍某工程大跨度悬挑预应力混凝土梁施工概况,针对梁柱节点预应力束准确定位难、局部受压面积不足 易出现裂缝,模板支撑体系拆除产生下挠3个间题,分析3个难点出现的根本原因并提出了解决方案,同时述了 后张法有粘结预应力混凝土梁施工控制要点. [关键词]混凝土;预应力;悬挑梁;裂缝;施工技术 [中图分类号]TU745.2 [文献标识码]A [文章编号]1002-8498(2017)15-0046-03 Construction Difficulties and Control Keypoints of an Engineering Prestressed Cantilever Beam ZHANG Wei ZHOU Zhijun LI Yang ZHANG Zhongshan BAO Zheng (China Construction Serenth Engineering Dirision Co.Ltd.Zhengzhou He'nan 450004 China) Abstract:This paper introduces a project of large span cross cantilever construction of prestressed concrete beam.According to the problems of pinpoint difficulty of beam and column joint prestressed tendon that local pression area is not enough it is easy to crack and that the formwork support system is dismantled to produce deflection the reasons for difficulties and corresponding solving schemes are analyzed and the construction control keypoints for post tensioned bonded prestressed concrete beam are described. Key words:concrete;prestressing;cantilever beam;cracks;construction 1工程概况 平面布置如图1所示.预应力混凝土梁所采用的波 某商业工程位于郑州市区,总建筑面积约51万 纹管直径为70mm 2根预应力混凝土梁和1根普通 m2.由A B C.D座组成,地上18层,建筑高度为框架梁其上部纵筋均为2排o25 则节点处有2条 79.9m 整个工程2~18层的各层外围均为大跨度 波纹管、6排25上部纵向钢筋穿过,且框架柱主筋 预应力混凝土悬挑梁,悬挑跨度平均为15m 2根预 直径较大、箍筋密集,导致波纹管无法穿过且预应 应力混凝土梁与1根普通框架梁在梁柱节点交叉,力束曲线节点处竖向位置偏差过大,严重影响工程 预应力混凝土梁的张拉端均为双孔形式,截面尺寸 结构质量,如何保证预应力束曲线依照深化设计施 多为450mm×1400m...