2016年2月上 施工技术 第45卷第3期 CONSTRUCTIONTECHNOLOCY DOI:10.7672/sgjs2016030009 空间网格结构相贯节点全熔透区域焊缝检测技术 赵文雁,娄峰,陈君,柳跃强 (浙江精工钢结构集团有限公司,浙江绍兴312030) [摘要]以广州宏城广场空间网格结构相贯焊缝定量检测为背景,通过计算确定全熔透区域的范围,绘制无损检测 (NDT)图,利用超声波探伤技术对焊缝进行定量检测,检测结果表明采用该方法的焊缝质量满足规范要求。
[关键词】钢结构;空间结构;相贯节点;全熔透;焊缝;检测 [中图分类号]TU392.3 [文献标识码】A [文章编号〕1002-8498(2016)03-0009-03 TheCJPWeldInspectionTestingTechnologyofSteelTubular IntersectingJointsforaSpaceFrameStructure Zhao Wenyan,Lou Feng,Chen Jun,Liu Yueqiang (Zhejang Jinggong Steel Building Group Co.,Ld.,Shaoxing,Zhejiang 312030,China) Abstract:Taking Guangzhou Hongcheng Plaza intersection weld quantitative detection as an example,the regional scope of full penetration is determined through the calculation,nondestructive testing(NDT) drawingsisdrawn,quantitative detectionof weldsisdetected byusing ultrasonic detection technology. The quality of weld seams can meet the requirements of codes. Key words:steel structures; spatial structures;intersection joints;full welding;weld seams;detction 1工程概况 鱼尾网壳1一 面层网壳 广州宏城广场综合体天幕采用单层网壳结构, 鱼尾网壳2 主要由竖向支承与单层网壳2部分组成。
竖向支承 由树形柱、多脚支承、落地桁架3部分组成,竖向支 底层网壳 承与网壳通过销轴连接,与下部基础采用铸钢球铰 支座连接牢靠。
钢结构天幕共由5块单层网壳构成,局部区域 网壳有重叠,重叠区域高差约800mm,在高差范围 内通过设置斜腹杆做成类似平面桁架的形式进行 落客棚网壳 上下层网壳连接。
网壳构成如图1所示,重叠区域 连接构造如图2所示。
图1钢结构天幕网壳构成 单层网壳由若干个菱形网格构成,网格尺寸 Fig.1 Composition of velarium shell 约2m×2m,天幕中间区域网格内角在75°左右,各 2圆管相贯节点焊缝质量要求 网格形状基本一致,偏差较小。
边缘区域收边导 一般圆管相贯焊缝应沿全周连续焊接并平滑过 致杆件间夹角离散性较大,在15°~150°。
网壳杆 渡。
支管壁厚≤6mm时可采用全周角焊缝。
支管 件采用圆管截面,圆管外径统一为194mm,壁厚分 壁厚>6mm的相贯节点焊缝,相贯线焊缝根据主支 6,12,25mm3种规格,其中网壳之间连接腹杆采 管夹角Φ和局部两面角(圆管外壁间的夹角)的范 用Φ89×8圆管,圆管材质均为Q345B。
圆管之间 围分为全熔透区域、部分熔透区域和角焊缝区域,如 通过相贯节点部分熔透焊缝连接。
表1所示。
局部两面角<60°时,焊缝计算厚度应 [作者简介]赵文雁,南方事业部副总工程师,E-mail:zhaowenyan418 考虑一定折减,折减值如表2所示。
相贯节点分区及 @qq. 主支管夹角Φ和局部两面角如图3,4所示。
其 [收稿日期】2015-09-16 中,为较薄杆件壁厚,WP为工作点。
万方数据
10 施工技术 第45卷 B[区 C区 图2网壳重叠区域连接构造 图3节点局部两面角示意 Fig.2Connecting structure of overlapping zones Fig.3Dihedral angles in joints 表1相贯焊缝定性要求 3圆管相贯线节点全熔透区域焊缝质量检测 Table 1Intersecting weld seams qualitative requirements 3.1相...