施工技术 2015年10月上 24 CONSTRUCTION TECHNOLOGY 第44卷第19期 D0I:10.7672/8js2015190024 跳仓施工坑顶支座大梁长度变化实测与理论分析 赵明 (浙江广播电视集团,浙江杭州310005) [摘要]上海世茂深坑酒店坑顶支座大梁采用跳仓法施工,大梁底部设计有无胎卷材防水层.通过对大梁浇筑后 温度和长度变化的测量与计算,分析出无胎卷材防水层在减少垫层对大梁约束中的作用,以及先浇仓段对后浇仓 段的约束影响.经研究得出,在位于坚硬地基上的垫层上面铺设3mm厚无胎卷材防水层后,垫层与上部混凝土结 构之间的摩擦系数4为0.827. [关键词]混凝土;跳仓法;梁;约束;摩擦系数 [中图分类号]TU375.1 [文献标识码]A [文章编号]1002-8498(2015)19-0024-04 Temperature and Length Measurement and Theoretical Analysis of Support Beam Constructed by Jump Warehouse Method Zhao Ming Zhejiang Radio TV Group Hangzhou Zhejiang 310005 China) Abstract:The support beam of Shanghai Shimao Chasm Hotel is constructed by jump warehouse method and there is PET coil waterproof layer under the beam.By measuring and calculating temperature and length change of the beam this paper analyzed the constraint influence of coil waterproof layer in reducing the constraint between cushion and beam.After laying 3mm coil waterproof layer on the cushion covering hard foundation the friction coefficient between cushion and concrete strueture is 0.827. Key words:concrete;jump warehouse method;beams;constraint;friction coefficient 0引言 采用跳仓法施工的混凝土结构,对于单个仓段 温度变化和尺寸变化的研究以及仓段之间相互约 束的研究目前较为少见.上海世茂深坑酒店项目 坑顶支 坑顶 坑顶支座大梁截面尺寸为3.2mx2.25m 采用跳仓 座大梁 裙房 法施工,由于大梁截面尺寸较大,混凝土施工时大 梁内部温度较高,温度引起的长度变化较为明显, 坑内主体 以坑顶支座大梁为研究对象,对防水层在减少垫层 对大梁约束中的作用,以及先浇仓段对后浇仓段的 图1坑顶支座大梁位置示意 约束影响进行研究. Fig.I Position of the support beam 1工程概况 进行覆盖,定期洒水,侧面模板晚拆.现场温度和 坑顶支座大梁位于坑边上口,大梁底部垫层位 长度测量装置埋设在大梁第1仓段和第2仓段内,2 于坚硬的安山岩上.大梁采用C40混凝土,配筋率 个仓段分别代表单仓段...
推荐内容/By 图集吧
- 王晓军-刚域长度的计算及其对结构分析和设计的影响.pdf
- 蔡国强-钢筋混凝土梁挠度计算方法研究.pdf
- 隋庆海-关于倾覆弯矩规范法与轴力法计算结果不同的分析与讨论.pdf
- PKPM结构计算结果分析实例.doc
- 装配式部分预应力砼简支梁计算书.doc
- 平板式筏基计算方法的改进和简化.pdf
- 中建模板支架、外脚手架标准计算手册.pptx
- 平整场地计算规则.doc
- T/QGCML 4134-2024 用于固定长焊缝待焊件的工装夹具及搅拌摩擦焊系统.pdf
- GB/T 37525-2019 太阳直接辐射计算导则.pdf
- Q/GDWZ 12341.2-2023 35kV~750kV输变电工程合理工期管理导则 第2部分:工程建设.pdf
- Q/GDWZ 12341.1-2023 35kV~750kV输变电工程合理工期管理导则 第1部分:工程前期.pdf