2012年5月上 施工技术 第41卷第364期 CONSTRUCTION TECHNOLOCY 57 既有建筑综合纠倾法设计与施工 王建平,朱思响,李品先 (西安建筑科技大学土木工程学院,陕面西安710055) 【摘要]通过某7层住宅楼的加固纠偏工程实践,综合应用钢筋混凝土托换桩加固和掏土浸水纠偏方法来对倾斜 的房屋进行纠偏.在纠偏过程中,对上部结构裂缝和地基沉降进行了观测,发现该住宅楼经处理后,倾斜量由最大 的125mm减小到10mm 最终倾斜率为0.39%,符合国家规范要求. [关健铜]加周:托换桩:房屋纠偏:浅层指土法:浸水法 [中图分类号]TU746.3 [文献标识码]A【文章编号]1002-8498(2012)09-005703 Design and Construction of Integrated Deviation Correction of Existing Building Wang Jianping Zhu Sixiang Li Pinxian (School of Civil Engineering Xi'an University of Architecture and Technology Xi'an Shaanxi 710055 China) Abstract:According to a 7-story residential building reinforcement correcting engineering prehensive application of reinforced concrete underpinning pile and dig soil soaking method of correcting is adopted. In the correction process the superstructure cracks and foundation settlement are monitored.The monitoring result shows that the deviation amount is reduced from the maximum of125mmto10mm the deviation ratio is about 0.39% which satisfies the requirement of national code. Key words:strengthening:underpinning piles;building deviation correction the method of drawing out earth;the method of soaking in water 近年来,由于地基处理不当或房屋使用等过程室.基础形式为钢筋混凝土条形基础,基底埋深 中的不合理因素造成地基不均匀沉降进而导致既 -2.75m.地基处理采用整片3:7灰土换填法,换 有建筑倾斜的事故不少.特别是我国西北部处于填厚度为2000mm.该楼主体完工后,发生不均匀 湿陷性黄土地区,常因排水不畅、地下管网渗水等沉降,整体倾斜,建筑物平面布置如图1所示.为查 原因造成地基不均匀下沉,使既有建筑倾斜.本文 明楼房倾斜现状,建设单位于2010-08-15对该楼倾 结合工程实例,研究了托换桩加固与掏土浸水综合 斜量进行了现场测量,结果如表1所示. 纠倾法在实际工程中的应用. 6 对建筑物的纠偏,常用方法主要有迫降法和顶 升法.迫降法就是人为增大建筑物沉降小的一侧...
推荐内容/By 图集吧
- 承压砂土地层桩洞法施工动态效应及其控制研究.pdf
- 地基沉陷导致房屋局部损坏的检测及加固处理.pdf
- 软土地层深基坑隆起变形规律及其对周围建筑物的影响.pdf
- 软土地区某多层房屋纠倾加固技术.pdf
- 某建筑修缮改造工程抗拔桩设计及讨论.pdf
- 某仿古建筑病害原因分析及应对措施.pdf
- 宁建科字[2023]172号《南京市既有建筑加固改造结构设计导则(试行)》《南京市既有建筑加固改造工程施工图设计文件技术论证和审查指南(结构专业)(试行)》
- 某工程CFG桩复合地基设计及施工.pdf
- 某仿古建筑病害原因分析及应对措施.pdf
- 某房屋抬升纠偏施工期结构形态监测系统的实现与应用研究.pdf
- 解析法和数值法在基坑降水和回灌系统设计中的综合应用
- 既有建筑高位基础加固及顶升纠倾施工