施工技术 2016年2月上 16 CONSTRUCTION TECHNOLOGY 第45卷第3期 DOI:10. 7672/sgjs2016030016 承插型套扣式钢管脚手架模板支撑体系应用 钟文深,李敏健,钟志峰 (广州市第一建筑工程有限公司,广东广州510060) [摘要】承插型套扣式钢管脚手架作为新型钢管脚手架,具有搭拆快捷、安全可靠、工效高等特点。
以广州宏城广 场综合改造工程为背景,介绍了承插型套扣式钢管脚手架在复杂造型商业广场中的应用情况,对脚手架的设计和 安装进行了详细阐述。
[关键词】脚手架;模板;支撑;套扣式脚手架;施工技术 [中图分类号】TU731.2 [文献标识码]A [文章编号]1002-8498(2016)03-0016-03 ApplicationofFormworkSupportsofNestedSteelTubularScaffolds Zhong Wenshen,Li Minjian,Zhong Zhifeng (Guangzhou Firs Construction Engineerng Co., Ld., Guangzhou, Guangdong 510060,China) Abstract:Nested steel tubular scaffold as a new type of steel scaffold has the advantages as disassembly and assembly quickly and easily, safely and reliably and effctively.Taking Guangzhou Hongcheng Plaza prehensive renovation project as the background,nested steel tubular scaffolds applications on plex mercial plaza, the scaffolds design and installation of the details are introduced. Key words:scafflds;formwork;supports;nested steel tubular scaffold;construction 随着我国基础建设的蓬勃发展,钢管脚手架的 使用广泛且多样。
套扣式钢管脚手架属于新型钢 管脚手架,具有搭拆快捷、节时省力、安全可靠、提 高工效等特点,已在多个工程项目中应用。
1工程概述 b横杆接头 广州宏城广场综合改造工程地下3层,地上2 层,总建筑面积约113500m²。
各层基本层高如下: 地下2层5.10~7.30m,地下1层6.15m,1层5.50 和6.55m,2层6.60m,天面7.25m。
楼板厚度分为 150,200,250mm3种,结构梁尺寸不等。
结构形状 复杂,弧形造型多,无标准层做法。
经综合考虑,最 c直插式套筒d可调顶托c可调底座f构件组装形式 终选用技术性和经济性较好、安全性较强、工期有 (U托) 优势的承插型套扣式钢管脚手架作为搭设高度8m 图1套扣直播式钢管脚手架组成 以下模板支撑体系,搭设量约400000m”。
Fig.1Compositions of nested steel tubular scaffolds 2承插型套扣式钢管脚手架组成 式钢管脚手架的对接扣件;横杆接头替代直角扣 承插型套扣式钢管脚手架由钢管立杆、套扣、 件;套扣、竖向接长套筒直接焊接在立杆上,变成三 横杆接头、直插式接长套筒、可调U托、可调底座、 件合一。
立杆和水平杆宜采用截面Φ48×3.2或以 抛撑接头7个部分组成(见图1)。
上规格的钢管,立杆长度分别有600,900,1200, 套扣替代扣件式钢管脚手架的连接扣件,是杆 1800mm和2400mm。
套扣在立杆上的间距宜按 件之间的连接构件;竖向直插式接长套筒替代扣件 600mm的模数设置。
立杆之间的连接应采用连接 [作者简介]钟文深,高级工程师,E-mail:20599514@q. 套管,其壁厚≥3.2mm,长度≥150mm,可插人长度 [收稿日期】2015-09-16 ≥100mm,套管内径与立杆钢管外径间隙≤1.5mm。
万方数据
2016 No.3 钟文深等:承插型套扣式钢管脚手架模板支撑体系应用 17 横杆接头直接焊接在横杆的两端,变成两件合 延伸至周边。
一。
水平杆的长度规格应与搭设的架体立杆常用 2)当架体高度>5m且≤8m时,应在中间纵横 纵距和横距(475,600,900,1000,1200mm和 向每隔4~6m设置由下至上的连续扣件式钢管竖 1500mm等)匹...