2014年10月上 施工技术 第43卷第19期 CONSTRUCTION TECHNOLOGY 39 D0I:10.7672/5gjs2014190039 超深等厚度水泥土搅拌墙在紧邻高架 深大基坑工程中的应用 李星,谢兆良,万星鹤 (上海广大基础工程有限公司,上海201404) [摘要]某超大、超深基坑工程紧邻高架道路,地质条件复杂,围护设计采用灌注桩排桩结合等厚度水泥土搅拌墙 悬挂式隔水帷幕,较好地解决了埋深超过60m的承压水问题,有效控制了对周边环境的影响.对试成墙的试验情 况和监测结果进行了详细的介绍. [关键词]地下工程;深基坑;水泥土搅拌墙;隔水椎幕;监测 [中图分类号]TU476.3 [文献标识码]A [文章编号]1002-8498(2014)19-0039-03 Application of Ultra Deep Cement-soil Wall with Uniform Thickness in Deep Foundation Excavation Adjacent to Viaduct Li Xing Xie Zhaoliang Wan Xinghe (Shanghai Guangda Foundation Engineering Co.Lid.Shanghai 201404 China) Abstract:The geological condition of some deep foundation excavation was very plex.The ultra deep cement-soil wall with uniform thickness was used to cut off the deep confined water which solved the problem of confined water with 60 meters depth and the surrounding environment was effectively protected.This paper introduced the test and monitoring result of wall forming. Key words:underground;deep foundation excavation;cement-soil wall;waterproof curtain;monitoring 1工程概况 "ul 用虹路 基地红线 虹桥商务区核心区一期08地块一Ⅲ-D13项 目位于上海市长宁区虹桥商务区内,项目四周紧邻 市政道路,且基坑南侧为高架桥,距离基坑约30m Il-D13地块 如图1所示.本工程地上拟建2~10层多层建筑, 川-D23地块 设置3层地下室,采用桩筏基础;基坑总面积约 46090m2 基坑总延长约892m 开挖深度约 为17.0m. 建虹露 基地红线 2工程地质条件 本工程基底处于④灰色淤泥质黏土层中,场地 分布有⑤,微承压水层,⑦承压含水层和⑧,承压 图1施工场地总平面 含水层,且大部分区域微承压水层与承压含水层连 Fig.1 Plan view of the excavation site 通,微承压含水层埋深仅20m 距离基底约3m.场 土搅拌墙隔水帷幕作为基坑周边围护体(见图2), 地内的工程地质条件及基坑设计参数如表1所示. 围护桩同时作为正常使用阶段地下室侧壁挡土结 3围护设计 构的一部分,即采用“桩墙合一技术”.基坑靠近 基坑围护设计采用灌注桩排桩结合800mm厚 ...