施工技术 2012年5月上 104 CONSTRUCTION TECHNOLOGY 第41卷第364期 大型设备预埋件定位测量技术 魏玉明,孔令杰,党星海 (兰州理工大季土木工程学院,甘肃兰州730050) [摘要]通过对兰州理工大学地震模拟台预埋件精密定位项目测量实例的介绍,分析了大型设备预埋件测量技术 的特点,阐述了精密定位的有关问题,并针对预埋件所处的特定地理位置和混凝土的浇筑情况,首次提出并采用一 次建立控制网的方法,并且充分利用前方交会、后方交会及自由设站等方法,也为今后大型设备测量技术的应用提 供了有效的途径和方法. 【关键词]测量;预埋件;精密定位;控制网;交会 【中图分类号]TU198.2[文献标识码]A[文章编号]1002-8498(2012)09-0104-02 Measurement Techniques for Large Equipment Embedded Part Wei Yuming Kong Lingjle Dang Xinghai School of Civil Engineering.Langhou University of Technology Lanzhou Gansu 730050 China) Abstract:By introducing precision positioning of embedded parts of earthquake simulator in Lanzhou University of Technology large equipment embedded parts positioning characteristics are analyzed some problems of the precise positioning are described.Based on specific geographic location of embedded parts and concrete pouring one time of establishing control network is firstly proposed and adopted forward intersection resection and free station and other methods are also fully used. Key words:measurement;embedded parts:precision positioning;control network;intersection 1工程概况 果统计出的边长测量精度为±0.2mm 方向精度为 兰州理工大学地震模拟振动台的基础中有8个±0.5,经实测对比,精度完全满足要求,因此先进 主要的预埋部件,其中14号位于基础坑底,与垂 行基坑底部1~4号预埋件的初步定位,初定后,对 直方向的加振器周连,控制上、下振动;5-8号位于1~2号距离采用多测回距离测量且采用经标定后 基坑侧面,与水平方向上的4个加振器固连,用来控的钢尺进行检核,其精度满足要求后,把1 2号点作 制侧向振动.这8个预埋部件要求很高的定位精为临控点,令1号点坐标为(1000 1000),然后根 度,精度要求0.4mm 英方提出预埋部件面板中心 据1~2号的距离,假定某一方位角,计算得到2号 在x y a B y六轴方向上的误差要<0.4mm.如 点的坐标,这样1 2号点坐标就是完全满足精度要 何控制6个方向的偏差是工程成败的关键. 求的点,利...
大型设备预埋件定位测量技术.pdf