2014年10月下 施工技术 第43卷第20期 CONSTRUCTION TECHNOLOGY 51 D0I:10.7672/8gjs2014200051 张弦管桁架结构张拉力优化分析* 李静斌,洪彩玲 (郑州大学土木工程学院,河南郑州450001) [摘要]张弦管桁架结构是预应力钢结构中的自平衡体系结构,数量众多的拉索是构成空间结构的关键.拉索预 应力导入过程对结构的施工过程和最终受力形态产生不可忽略的影响,以鹤壁市体育馆张弦管桁架钢屋盖为例, 应用张力补偿法进行拉索张拉控制力分析和张拉批次划分的分析,探寻其在施工过程中和施工完成后对结构受力 状态的影响. [关键词]桁架;张弦结构;张拉;优化;数值模拟 [中图分类号]TU394 [文献标识码]A [文章编号]1002-8498(2014)20-0051-03 The Optimization Analysis of Tension for Truss String Structure Li Jingbin Hong Cailing (School of Civil Engineering Zhengzhou University Zhengzhou He'nan 450001 China) Abstract:Truss string structure is one of the prestressed steel structure in the self-balancing architecture and a large number of cables is a form of spatial structure of the key.The prestress import process on the structure of the construction process and final force form can not be ignored.Taking the Hebi Stadium chord truss steel roof for example tension pensation method was applied for cable tensioning forces control analysis and tension batch analysis to explore the structure stress state in the construction process and pletion of the construction. Key words:trusses;truss string structure;tensioning;optimization;simulation 1工程概况 鹤壁市体育馆位于鹤壁市朝歌路与兴鹤大街 向北200m路西,造型呈“马蹄形”.结构形式为钢 筋混凝土框架、劲性混凝土及钢结构为一体的混合 结构,屋面为预应力空间管桁架,屋面板为铝镁锰 板,外墙由153只铝单板制成的千纸鹤组成.建筑 面积16666m2 钢屋盖结构如图1所示.体育馆屋 图1钢屋盖结构示意 盖为跨度80m的圆形平面,北侧局部切平并与跨度 Fig.1 Steel roofs structure 26m的矩形钢结构屋面相连,结构形式采用预应力 张弦管桁架焊接钢结构1,以圆心为基点间隔18° X26 X24 沿径向向外辐射,一侧支座为钢筋混凝土柱,另一 x28 X16 X14 侧支撑在直径20m的刚性环桁架上;刚性环桁架上 X3...