Contents 1General provisions (1) 2Terms and symbols (2) 2.1Terms (2) 2.2Symbols (2) 3Materials ..... (5) 3. 1 Steel materials and welding materials for strengthening 3.2 Post-poured concrete (6) 3.3Protection materials (6) 4 Design method (7) 4.1General requirements (7) 4.2S Strengthening of axially loaded members (8) 4.3 Strengthening of pression-bending members **** (10) 4. 4Detailing requirements *** (13) 5 Strengthening construction (16) 5.1General requirements (16) 5.2Construction requirements (16) 5.3Safety precaution (18) 6Inspection and acceptance (19) 6.1Inspection (61) 6.2 Acceptance (20) Explanation of wording (21) List of quoted standards (22) Addition:Explanation of provisions (25)
1总则 1.0.1为规范外套钢管混凝土加固混凝土柱技术的应用,做到 安全适用、技术先进、经济合理、质量可靠,制定本规程。
1.0.2本规程适用于工业与民用建筑和一般构筑物混凝土柱的 加固设计、施工及验收。
1.0.3采用外套钢管混凝土加固混凝土柱前,应按现行国家标 准《工业建筑可靠性鉴定标准》GB50144、《民用建筑可靠性鉴 定标准》GB50292和《既有建筑鉴定与加固通用规范》GB 55021的有关规定进行检测或鉴定;当与抗震加固结合进行时, 尚应按现行国家标准《建筑抗震鉴定标准》GB50023、《构筑物 抗震鉴定标准》GB50117和《建筑与市政工程抗震通用规范》 GB55002的有关规定进行抗震能力鉴定。
1.0.4外套钢管混凝土加固混凝土柱的设计、施工及验收除应 符合本规程规定外,尚应符合国家现行有关标准和现行中国工程 建设标准化协会有关标准的规定。
2术语和符号 2.1术语 2.1.1原柱existing column 实施加固前的混凝土柱。
2.1.2外套钢管混凝土加固法 structuralmember strengthe ning with jackets of steel tube and sandwiched concrete 在原柱外套两片半圆形或[形钢,现场焊接成外套钢管, 间隙灌注流动性良好的混凝土,使外套钢管与原柱形成整体性能 良好的组合柱,大幅度提升原柱承载力、刚度及延性的一种加固 方法。
2.1.3后浇混凝土post-pouredconcrete 实施加固时灌注在外套钢管与原柱间的混凝土。
2.1.4含钢率steelratio 外套钢管混凝土加固混凝土柱中外套钢管截面面积除以原柱 混凝土截面面积与后浇混凝土截面面积之和的值。
2.1.5套箍系数confinementcoefficient 外套钢管混凝土加固混凝土柱中外套钢管截面面积与钢材强 度设计值乘积,除以原柱混凝土截面面积与混凝土强度设计值乘 积、后浇混凝土截面面积与混凝土强度设计值乘积之和的值。
2.2符 号 2.2.1作用效应与抗力 M- 作用于加固柱的弯矩设计值; M 加固柱的受弯承载力; N- 作用于加固柱的轴心压力设计值; .2.
Ne 欧拉临界力; N- 加固柱的轴心受压承载力。
2.2.2 材料性能 E. 外套钢管的弹性模量; E, 原柱钢筋的弹性模量; E 加固柱的组合弹性模量; f 外套钢管的抗压强度设计值; fak 外套钢管的抗压强度标准值; fa 原柱混凝土的轴心抗压强度设计值; fa 后浇混凝土的轴心抗压强度设计值; few 加固柱的混凝土等效抗压强度设计值; f 原柱钢筋的抗压强度设计值。
2.2.3 几何参数 A- 加固柱的截面面积; A 外套钢管的截面面积; A 原柱混凝土的截面面积; Aa 后浇混凝土的截面面积; A, 原柱纵筋的截面面积; Ao 加固柱的截面净面积; b、h 外套矩形钢管的截面短边长度、长边长度; D- 外套圆形钢管的截面外径; lo 加固柱的计算长度; r...