目 次 总则 2 术语 (2) 3基本规定 (4) 4空调通风系统 (6) 4.1一般规定 ..... 4.2空调通风系统节能调适 (6) 4.3空调通风系统运行维护 (8) 5电气系统 (10) 5.1一般规定 (10) 5.2电气系统节能调适 (10) 5.3电气系统运行维护 (11) 6给水排水系统 (13) 6.1一般规定 (13) 6.2给水排水系统节能调适 (13) 6.3给水排水系统运行维护 (14) 7监测与控制系统 (16) 7.1一般规定 (16) 7.2 监测与控制系统节能调适 (16) 7.3监测与控制系统运行维护 (17) 8调适验收 ...... (19) 本规程用词说明 (21) 引用标准名录. (22) 附:条文说明. (23)
Contents General provisions (1) 2 Terms (2) 3 Basic requirements (4) 4Air conditioning and ventilation system (6) 4.1 General requirements ... (6) 4.2E Energy-saving missioning of air conditioning and ventilation system........ (6) 4. 3 Operation and maintance of air conditioning and ventilation systerm...... (8) 5 Electrical system.. (10) 5.1 General requirements .... (10) 5.2Energy-saving missioning of electrical system ..... (10) 5.3 Operation and maintance of electrical system . .(11) 6Water supply and drainage system (13) 6.1 General requirements ..... 6. 2 Energy-saving missioning of water supply and drainage system 6. 3 Operation and maintance of water supply and drainage ......sds 7Monitoring and control system (16) 7. 1 General requirements ..* (16) 7. 2 Energy-saving missioning of monitoring and control system .... (16) 7. 3 Operation and maintance of monitoring and control system ..... (17) 7.
8Acceptance for missioning Explanation of wording in this specification (21) List of quoted standards (22) Addition:Explanation of provisions (23)
1总则 1.0.1为加强地铁车站的节能运行,提高能源利用效率,降低 地铁车站的运行能耗,制定本规程。
1.0.2本规程适用于城市轨道交通地下车站空调通风系统、电 气系统、给水排水系统、监测与控制系统的节能调适和运行 维护。
1.0.3城市轨道交通地下车站机电系统的节能调适与运行维护 除应符合本规程外,尚应符合国家现行有关标准的规定。
2术语 2.0.1峻工调试testing,adjusting and balance of installation pletion acceptance 由监理单位监督,设计单位和建设单位参与和配合,施工单 位负责完成,满足工程峻工验收要求的调试过程,包括设备单机 试运转及调试,系统非设计满负荷条件下的联合试运转及调试。
2.0.2节能调适energy-saving missioning 在峻工调试的基础上,通过对建筑设备系统的调试验证、性 能测试验证、季节性工况验证和综合效果验收,使建筑设备系统 达到预定的使用功能和能效水平,满足不同负荷工况和用户使用 需求的过程。
2.0.3季节性验证seasonalvalidation 在典型季节对空调系统的制冷能力、室内环境效果、调控性 能、系统能效进行测试和验证的过程。
2.0.4项目需求书specificationofproject...