目次 1总则.. 2术语. 3基本规定.. 4水质、水量、水压、 3 5系统设计..... 5 5.1系统选择, 5.2流量与压力. 5 5 5.3管道布置. 6 6设备设施.. 8 6.1管材、附件和水表, 8 6.2水泵... 10 6.3水箱. 10 6.4消毒设备. 11 7泵房... 12 8控制与保护 14 8.1控制 14 8.2保护 14 9施工与验收 15 9.1一般规定. 15 9.2施工. 15 9.3验收. 17 本标准用词说明, 18 引用标准名录. 19 条文说明.
20
Contents 1General provisions. 2 3Basic requirements.. 4 Water quality、water quantity、 water pressure.. 4 5System design.. .5 5.1System selection... 5.2 Design flow and hydraulic pressure. .5 5.3Piping layout. .6 6 Equipment and facilities. 6.1 Pipe materials、 appurtenances and water meters... 8 6.2 Water pump.. .10 6.3 Water tank. ..10 6.4 Disinfection cquipments.. ..1 o dund .12 8Control and protection. 14 8.1 Control.. ..14 8.2 Protection. 14 9 Construction and acceptance.. ..15 9.1 General requirements.. .15 9.2Construction... 15 9.3Acceptanc... .17 Explanation of wording in this standard.. List of quoted standards. 19 Explanation of provisions. 20
1总则 1.0.1为规范山东省新建住宅小区供水设施建设,提高住宅小区供水设施的建设和管理水 平,制定本标准.
设施的设计、施工及验收.
1.0.3住宅小区供水设施的建设应符合国土空间规划相关要求.
1.0.4新建住宅小区生活供水设施的设计、施工及验收,除符合本标准外,尚应符合国家及 山东省现行有关标准的规定.
2术语 2.0.1住宅小区供水设施 water supply facilies in residential area 城市规划建设用地范围新建住宅小区建筑区划红线之内室外、室内生活供水设施的总 称.
2.0.2供水设施water supply facilities 为住宅小区供水设置的泵房、供水管道、阀门、管件、水表、水箱、压力水容器、水泵、 电控装置、消毒设备、水处理设备、水质监测设备等设施.
2.0.3叠压供水pressure superposed water supply 供水设备从有压的供水管网中直接吸水增压的供水方式.
2.0.4引入管service pipe 由市政供水管道引入至住宅小区供水管网的管段,或由住宅小区供水接户管引入建筑物 的管段.
3基本规定 3.0.1供水设施应具有应对自然灾害、事故灾难、公共卫生事件和社会安全事件等突发事件 的能力,设施运行管理单位应制定有关应急预案.
3.0.2供水设施工程的防洪、防涝标准不应低于所在区域城镇设防的相应要求.
3.0.3供水设施应选用节水、节能设备和产品.
3.0.4供水设施中的涉水产品应符合现行国家标准《生活饮用水输配水设备及防护材料的安 全性评价标准》GB/T17219的有关规定.
3.0.5供水设施应采用远程监控、网络安全运行等智能化技术.
3.0.6二次供水设施不得影响城镇供水管网正常供水,并应有保证管网压力稳定的措施.
当 采用叠压供水时应经当地供水单位同意.
3.0.7施工应按工程设计文件和施工技术标准进行施工安装,不得擅自修改工程设计.