1H3C交换机巡检命令 1.1查看CPU使用率 displaycpu-usage Slot1 CPU usage: 6% in last 5 seconds 5% in last 1 minute 5%in last 5 minutes #最后5分钟的平均使用率为5%# Slot1CPU1CPUusage: 0% in last 5 seconds 0% in last 1 minute 0% in last 5 minutes 1.2查看内存使用率 displaymemory System Total Memory(bytes):874453360
Total Used Memory(bytes):117120680 Used Rate:13% #内存使用率为13%# 1.3查看设备温度信息 display environment Slot 1 System temperatureinformation(degree centigrade): Sensor TemperatureLowerLimitWarningLimitAlarmLimitShutdownLimit Inflow1 32 0 67 72 NA hotspot1 38 77 82 NA #hotspot:表示热点温度传感器 inflow:表示入风口温度传感器 目前slot1入风口入设备温度为32度,热点温度为38度,设备温度一般指热点温度 1.4查看设备汇总信息
display deviceverbose Slot 1 SubSNoPortNum PCBVerFPGAVer CPLDVer BootRomVer AddrLM Type State 0 30 REV.B NULL 003 210 IVL MAIN Normal slot 1 info: UpTime :10weeks 0 days 6hours 26minutes Brd Type :H3CS5500-34C-HI-D Brd Status:Master Sft Ver :5.20Release5203P03 Patch Ver:None PCB Ver :REV.B BootRomVer:210 CPLD Ver:003 #可查看到设备的运行时间,设备型号# 1.5查看风扇信息
display fan Slot 1 FAN 1 State Normal #查看风扇的状态,Normal为正常,Abnormal为异常# 1.6查看电源信息 displaypower Slot 1 InputPower :63(W) Power 1 State Normal Type : AC/150(W) Power 2 State :Fault Type :Unknown
#查看电源的状态,Normal为正常,Abnormal为异常# 1.7查看时间 display clock 17:08:12 UTC Mon 11/24/2014 #查看时间是否正确# 1.8查看接口详细信息 displayinterfacebrief The brief information of interface(s) underroute mode: Link:ADM-administratively down;Stby-standby Protocol:(s)-spoofing Interface LinkProtocol MainIP Description M-GE0/0/0 DOWN DOWN NULLO UP UP(S) Vlan1 UP UP 192.168.0.100 The brief information of interface(s) underbridge mode:
H3C交换机巡检命令.docx