HPProliant系列服务器阵列配置 开机自检到阵列卡界面,在阵列卡初始化完之后,会出现配置阵列的快捷键, 如图1示: 2048 HB Detected DroL1ant Systan BI0s-p29 (05/01/2004) Copyright 1982 2004 Hevlett-Packard Development Group L.P. Processor 1 initialized at3.20 GHz/533 mHz(512 KbyteL2 1 Myt L3) Processor 2 initialized at 3.20 GHz/533 HHz(S12 Kbyte L2 1 Hbyte L3) dvanced Heaory rotection Hode:Advanced Cc Support sss ss- Integrated Lights-0ut Advanced 1.82 Aug 22 2005 10.0.1.241 1ot0 suare Arroy Ss Controller (64HE V2.38) SATIG TTBO Press to run the Option Ron Configuration Press to skip configuration and continue for Arrays Utility 图1 按F8进入ORCA配置界面i(ORCA=Option Rom Configuration for Arrays): 出现主菜单,界面如图2示:
Option Ron Configuration tor Axrays version 2.06 Copyright 2003 Heulett-Packard Developxent Coapany L.P. Controller: HP Saart Array Si slot0 Direct-Attached Storage Create LovicalDrive Hain Henu Vieu Logical Drive Delete Logical Drive toselect main menu option; Enters to create aneu Logical drive <ESC 图2 新硬盘配置新阵列的话,请选择CreateLogicalDrive,进入后,如图3示: Option Roa Configuration tor Arrays versicn 2.D6 Copyright 2003 Heulett-Packard Developaent Company L P. Direet-Attached Storage Controller: HP Smart Array Si slot 0 kwailable Physical Drives Raid Contigurations []SCSIPort2IDO COHPAQ 10.2CB 36.4CB []RAIDS RAID 1(10) []SCSI Port2 ID3 COHPAQ 36.4CB [X]RAID0 El Use one drive an spare -Spare= Haximn Boot partition to seroll:<ESCx toreturm: toselect 图3 在配置界面的左侧,是阵列卡所连接的物理硬盘,右侧上面是阵列级别选项, 右侧中间是HOTSPARE盘的选项,下面是Maximum Bootpartition选项(此 选项用在WindowsNT4.0操作系统上,用来选择最大启动分区,可选择默认选 项) 现在用2块硬盘做raid1,加一块硬盘做HOTSPARE,选择一块18.2gb,一 块36.4gb作为raid1,一块36.4gb做HOTSPARE(注:raid1级别,两块硬 盘容量必须一致,如果不一致,以最小容量的盘为准) 按SPACE键(空格键)选择2块硬盘,选择成功后会在[]前面有X的提示, 如图4:
Option Rom Configuration for Arrays version 2.06 Copyright 200s Hawlatt-Dackard Davelopment Company L.P. Direct-Attached Storaga Controller:Hp Smart Array S1 slot0 Available Dhysical Drivas= Paid Confsgurations 36.4CB [X1DAID1(10) L]RAID5 IX] SCSI Port 2.1D1,COMPAQ 1SCSTPort2.TD3,COMPAQ 36.4CB ]RAIDO []Useonedrive asspare Spare laxiam Boot partition []Enable (SCBmaxin) to create a logical driva; to navigata toscroll:<EsCtoreturn: to select 图4 选择物理盘后,按TAB键到右侧上面,来选择阵列级别,ORCA自动识别为 raid1 如图5示:
Option Don Configuration tor Axray= vers1on Z.06 Copyright 2003 Heulett-Packard Developaent Coapany L.P Controller: HP Snart Array Si slot 0 Direct-Attached Storage Available Physical Driver= Paid Configurations 1X1 scsIPort2.D 0 CCPAQ 36.4CB [X]DAID1[240) []PAIDS 11SCSI Port [X]scsI Port 2.日 1 COPAQ 10.2CB 日 3.COHPAD 36.4CB 1RAIDO Spare L1 Uze onadriveaz spare ariau Boot partition []Enable (808) toseroll:toreturn to creataa logical drive; to navigate 图5 再按TAB键到Spare选项,来选择HOTSPARE盘,依旧按Space键来选定, 选择后如图6示: